Below are some simple Diagrams to show the potential uses of the Flexicap Continuous Level Indication.
Continuous capacitance stand alone probe
A capacitance probe works in two ways - with Conducting liquids and non-conducting liquids.
The capacitance principle is two detector plates and one insulator. By changing one of the factors you can measure its change and give a continuous output signal.
For conducting liquids
Use a metal rod which is insulated. As the conducting liquid rises and falls in the tank.
The change is detected and a signal is produced
For NON conducting liquids.
use two concentric or parallel rods and the non conducting liquid rises and falls within the orifice or gap. The change is detected and a signal produced
You will need to choose the probe length in advance.
using this system you can measure to the top of the tank and it is unaffected by foam or turbulence
Continuous Capacitance probe & Controller
A capacitance probe works in two ways - with Conducting liquids and non-conducting liquids.
The capacitance principle uses two detector plates and one insulator. By changing one of the factors you can measure its change and give a continuous output signal.
For conducting liquids
Use a metal rod which is insulated. As the conducting liquid rises and falls in the tank.
The change is detected and a signal is produced
For NON conducting liquids.
use two concentric or parallel rods and the non conducting liquid rises and falls within the orifice or gap. The change is detected and a signal produced
You will need to choose the probe length in advance.
using this system you can measure to the top of the tank and it is unaffected by foam or turbulence
The probe will give a signal over its length and it will be detected by the controller
the controller will give digital indication, 4 programmeable trip points and a diagnostic trip point to detect cable break and shoirt circuit between the controller and the probe
Continuous capacitance flexible probe and controller
FLEXICAP variable capacitance systems with Flexilevel Wall Mounted Unit and cable probe lengths over 3 metres and up to 13 metres
A capacitance probe works in two ways - with Conducting liquids and non-conducting liquids.
The capacitance principle uses two detector plates and one insulator. By changing one of the factors you can measure its change and give a continuous output signal.
For conducting liquids
Using an insulated cable with a stainless steel conductor. As the conducting liquid rises and falls in the tank.
The change is detected and a signal is produced
For NON conducting liquids.
use two concentric or parallel rods and the non conducting liquid rises and falls within the orifice or gap. The change is detected and a signal produced
You will need to choose the probe length in advance.
using this system you can measure to the top of the tank and it is unaffected by foam or turbulence
The probe will give a signal over its length and it will be detected by the controller